A portable monitoring device using conductive cell technology for accurate, periodic measurements of the Acid Dewpoint Temperature (ADT) in combustion processes. 

Designed specifically to provide the unique but vital measurement of sulphuric acid dewpoint temperature, the portable Lancom 200 supports boiler efficiency checks, corrosion protection, and the management of high-cost fuel additives.

Easy-to-use ADT monitoring lets boiler operators balance acid emissions with efficiency, reducing the risk of corrosion in the boiler and wasted heat/fuel. This lowers operational costs and reduces harmful sulphate aerosol emissions.

Incorporating 40 years of AMETEK Land’s application expertise, Lancom 200 obtains an accurate reading in minutes. By generating a measurable current when sulphuric acid forms on the conductive cell, it makes a direct measurement for ADT.

Specially developed for plants requiring only periodic monitoring of sulphuric acid dewpoint temperature for boiler efficiency, the Lancom 200 is suitable for applications in the hydrocarbon processing and power generation industries.

Have questions? Call +61 2 9622 6327

ACCURATE MEASUREMENTS OF ADT
Using a conductive cell technique to measure the sulphuric acid dewpoint temperature, the Lancom 200 is accurate to within ±0.5°C, allowing a precise calculation of both sulphuric acid and sulphur trioxide concentrations, vital for optimum combustion efficiency and emissions compliance.

A PORTABLE SOLUTION
Weighing just 10kg (22lb), the device is easily carried around the plant. It operates from mains supplies or for up to eight hours using internal battery power. All that’s needed is a local compressed air supply and a suitable sampling point for probe access.

SIMPLE TO SET UP AND MEASURE
Just one person is required to set up and operate the Lancom 200, obtaining complete measurement data in just a few minutes. The built-in screen makes it easy for operators to maintain the required steady current flow.

The portable Lancom 200 is AMETEK Land’s dedicated solution for sulphuric acid dewpoint monitoring.

  • Boiler/Furnace operation
Measuring Technique:Conductive Cell Technique
Acid Dewpoint Temperature:120 – 200 °C (248 – 390 °F) Displayed in °C or °F.
Flue Gas Temperature:0 – 450 °C (32 – 840 °F) Displayed in °C or °F
Calculated Values:H2, SO4, SO3, Minimum Metal Temperature (MMT)
Uncertainty:± 0.5 °C dewpoint temperature
Resolution:0.1 °C
Detection Limit:Application dependent, typically 125 °C (257 °F) or 5 ppm SO3
Control Unit
Display:1/4 VGA Color LCD
Data Logging:All data values logged. Log interval 1 sec. to 10 min.. Storage for > 10000 records. Rechargeable battery 2 x 6 V 4 Amp. hour. Typical 8 hr. operation
Compliance and Environmental
Power Supply:95-265 V a.c. ±10%, 50-60 Hz, 30 Watts
Electrical Safety:EN 61010-2
EMC:EN 61326 (industrial)
Protection from Dust & Water:Instrument in bag; IP42 of BS EN 60529, Probe: IP65 of BS EN 60529
Vibration (Probe Only):BS EN60068-2-6 (10 Hz to 150 Hz at 19.6 ms-1 )
Operating Temperatures:-20 to +50 °C (-4 to 122 °F)
Inputs/Outputs
Modbus Communications:RS232/RS485 Isolated 2-wire, RTU mode, 19200 baud, 8 data bits, even parity, 1 stop bit
4-20 mA Outputs:8 channels (4 – 20 mA) ±0.1 mA non-isolated, 300 Ω max
USB Interfaces:USB master for Flash Memory devices. USB function ActiveSync for connection to a PC
Air Requirements
Air Supply:Clean, dry, oil-free air, 4-10 bar (60 – 150 psi)
Flow Rate:1 to 150 l/min (0.05 to 5 cfm) at 4 bar (60 psi), Max. 600 l/min (20 cfm)
Air Connection:ISO G3/8 (3/8 BSPP) male thread supplied
Mechanical
Overall Size in Carry Bag:500 x 225 x 300 mm (20 x 9 x 12 in.)
Weight (incl. Bag and Hoses):9.8 kg (22 lb.)
Cables and Hoses:2 air hoses, signal and power cables supplied, all 3 m (10 ft.)
Sample Probe
Material:Stainless Steel
Detector:Pyrex glass with platinum electrodes
Probe Access Port:Minimum requirement 50 mm / 2 inches diameter
Insertion Length:1.2 m (4 ft.) standard; Optional 2.1, 3.0 m (7, 10 ft.)
Weight (in Bag):6.2 kg (14 lb.), 8.6 kg (19 lb.), 11 kg (24 lb.)

 