Smart environmental monitoring solutions

Talk to our sales team. Call +61 2 9622 6327

Request a quote
Back to products
JCT-JH3FG-JH3FGR

JCT JH3FG & JH3FGR

Heated Sample Lines with PA-Protection Braid

  • For extractive gas analysis
  • For emission and process monitoring
  • For transport of sample gas from the sample point to the analysis system
  • To stay safely above the acid dew point
  • For protection against measured value falsification and frost
  • For indoor and outdoor use
  • Applicable for portable systems

Have questions? Call +61 2 9622 6327

Benefits

  • No condensate formation, no freezing
  • Close bending radius possible
  • Excellent thermal insulation
  • Optimal heat deployment
  • Customized configurations
  • Easy exchange of the inner core (JH3FGR)
  • Long lifetime also in portable applications
  • Kink protection

Features

  • Regulated heatable to max. 200 °C
  • External jacket flexible protection braid of polyamide
  • Heat insulation with silicone foam
  • Ready for use
  • Very flexible
  • Interchangeable inner core for JH3FGR
  • Second core for e.g. calibration gas as option
  • Integrated temperature controller as option
  • Inner core reinforced with stainless steel braid
  • For extractive gas analysis
  • For emission and process monitoring
  • For transport of sample gas from sample point to analysis system
  • To stay safely above the acid dew point
  • For protection against measured value falsification and frost
  • For indoor and outdoor use
  • Applicable for portable systems

 

MODELJH3FGJH3FGR
Descriptionregulated heated sample line
External protection jacketPolyamide braid, black
Inner corefixedinterchangeable
Area of applicationmobile and fixed indtallation indoor and outdoor
Operation Data
Operating temperaturemax. 200°C
Operating Pressuremax. 10 bara
Ambient temperature*-30°C to +60°C
Construction
Material inner corePTFE, optional PFA
Heating elementdesign according to DIN moisture proof with protection braid
Thermal insulationclose pore, waterproof Silicone hose, thermally stabilised
End configurationhard caps or Silicone caps (see below)
Maximum sample line lenght*50 m
Diameter core / sample line outsideDN 4/6 mm / 42 mm +/- 3 mm
DN 6/8 mm / 42 mm +/- 3 mm
DN 4/6 mm / 42 mm +/- 3 mm
DN 6/8 mm / 48 mm +/- 3 mm
Minimum bending radius JH3FG / JH3FGRDN 4/6 mm; 50 mm / 100 mm

DN 6/8 mm; 75 mm / 120 mm

Dimensions of silicone caps [mm]DN 4/6: L = 88, Ø 50 (H), Ø 70 (C)
DN 6/8: L = 88, Ø 50 (H), Ø 70 (C)
Dimensions of PA hard caps [mm]DN 4/6; L = 111,Ø 50 (F),Ø75 (A)

DN 6/8; L = 111,Ø 50 (F),Ø75 (A)

DN 4/6; L = 111,Ø 50 (F),Ø75 (A)

DN 6/8; L = 120,Ø 54 (F),Ø79 (A)

Protection classIP 44 (EN60529)
Electrics
Power supply230 VAC 50/60 Hz or 115 VAC 50/60 Hz
Power consumption100 W/m
Connection cable3 m
Connection Plug7-pole plug for connection of temperature controller HT-43 and HT-55
HANQ8-plug for connection of temperature controller HT-41
Option integrated temperature controller HT 54
Installation sitedirectly on hard cap end
Power supply230 VAC 50 to 60 Hz / 115 V 60 Hz
Switching capacitymax. 1000 W / 5 A (max. 10 m 230 V and 5 m at 115 V)
Temperature range0°C to 254°C, adjustable in 2°C steps via DIP-switch
Temperature sensorPT 100
Housing materiaPA-reinforced glass fiber
Protection classIP 42
optional sealed: IP 65 (fixed temperature adjustment)

DOWNLOADS

You have successfully subscribed to our newsletter!