- Complete turnkey system, would normally comprise of:
• Sample extraction and conditioning probe (with integrated temperature, pressure and flow measurement).
• Heated sample line in association with HOFI, heated sampling system according to the application
• Automatic calibration unit
• Instrument Air drying system
• Industrial PC with Windows based eSAM FT software for on-board data acquisition and processing - TOC measurement by FID possible, using the complementary Graphite 52M analyzer
- Complete turnkey system, would normally comprise of:
ENVEA MIR-FT
FTIR Multi-Gas Analyser
With the emissions limits tightening and new gases being introduced, this monitoring system allows future gas upgrades, providing the solution for today and what may happen tomorrow. Designed to operate under legislation such as 2000/76/EC (WID) and 2001/80/EC (LCPD), the MIR-FT offers maximum availability and complete compliance with QAL 1 of EN14181 & EN15267-3
- A single analyzer for the measurement of multiple gases : NO, NO2, NOx, N2O, CO, CO2, SO2, HCl, HF, CH4, TOC, NH3, H2O, O2 …
- Based on a leading edge technology for simultaneous, multigas measurement of: HCl, NO, NO2 (NOx), SO2, CO, CO2, HC, CH4 (TOC), NH3, HF, H2O…
- Fast and simultaneous measurements of up to 50 parameters
- Especially designed to measure wet and corrosive sample gases, including trace concentrations
- Perfectly suited for hot/wet measurement of soluble gases such as HCl, HF, NH3
- Excellent calibration stability
- Automatic correction of spectral interferences
- Unmatched accuracy and reliability
- Rugged & insensitive to vibrations
- Low maintenance required
Specifications
MEASURABLE PARAMETERS | ||||
---|---|---|---|---|
Pollutant | Range (ppb) |
Product code |
||
HCI | 0-15 / 500 | – | ||
HF | 0-3 / 100 | – | ||
NO | 0-200 / 2000 | – | ||
NO2 | 0-200 / 2000 | – | ||
N2O | 0-100 / 500 | – | ||
NOx | 0-200 / 2000 | – | ||
SO2 | 0-75 / 20000 | – | ||
CO | 0-75 / 10000 | – | ||
CH4 | 0-15 / 1000 | – | ||
THC | 0-50 / 1000 | – | ||
NH3 | 0-15 / 500 | – | ||
H2O(%) | 0-30 / 40 | – | ||
CO2(%) | 0-10 / 30 | – | ||
O2(%) | 0-10 / 25 | – |
Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)
(*) Min/Max based on 100/200 Dilution Rate (other ranges & dilution rates available upon request)
TECHNICAL SPECIFICATIONS | |
---|---|
QAL1 to EN 15267-3 certified | YES |
US EPA compliance | YES |
Sampling technology | Hot/Wet Extraction |
Sample transfert | 180°C heated sampling line |
back flush function | YES |
span injection | YES on analyser or at sample point |
Built-In O2 option | YES |
Serial link communication | / |
Other Communication | Ethernet |
Analogue OUTPUTS | Optional |
Analogue INPUTS | Optional |
Dimensions (mm) | 19” rack: 616 x 483 x 220 (DxWxH) |