- Automatic spectral interference correction
- Reproducible and accurate, fast response time
- Excellent calibration stability
- Acquisition and integration of 5 additional measurements (P, T, flow… and analogic parameters)
- Remote access for maintenance and configuration backup
- Graphic LCD screen, with interactive menu driven software
- Up to 60 m of heated sampling line (25 m standard version)
- Equipped with LAN connection for remote control and display functions and embedded Communication Protocol for WEX® Management Software and interactive menu-driven display allowing user-friendly and intuitive interface for the operator
- Embedded HMI with Graphic LCD display and interactive menu driven firmware, no computer required
- Remote access for all analyzer functions (visualization/ maintenance / configuration / backup…)
- Optimized operation cost (low maintenance and low consumables requirement)
- A full range of equipment is available to make the analyzer MIR 9000H an automated measurement system (probes & sampling box / sample line / module for automatic calibration / air treatment module / terminal module for I / O signals…)
ENVEA MIR9000H
Heated Multi-Gas Analyser Infra-red GFC
The MIR 9000H is a multi-gas infrared analyzer using the Gas Filters Correlation technology (GFC). With its hot measurement principle (180°C on a hot and humid sample), the MIR 9000H is the perfect tool for the analysis of the main gas parameters in many applications, including DeNOx (SCR / SNCR) and the optimization of flue gas treatment processes.
Continuous stack emission monitoring gas analyzer available in 2 versions for the simultaneous and continuous measurement of:
- NH3 and H2O
- CO, CO2, NO, NO2, SO2, HCl, HF, O2 in addition to NH3 and H2O (Multi gas Version / 8 parameters max)
- Designed to measure wet and corrosive samples
- TÜV certified as compliant to the European standard EN15267-3
- QAL 1 certified analyzer for the guarantee of accurate measurements
- Perfectly suitable for the ammonia slip detection
- 180°C heated measurement cell
- Robust design with a stainless steel tight box enclosure to withstand the harshest industrial environment
- Acquisition / management of peripherals measurements (particulates, temperature, flow…)
Specifications
MEASURABLE PARAMETERS | ||||
---|---|---|---|---|
Pollutant | Range (ppb) |
Product code |
||
HCI | 0-100 / 5000 | – | ||
HF | 0-40 / 300 | – | ||
NO | 0-200 / 5000 | – | ||
NO2 | 0-200 / 5000 | – | ||
NOx | 0-200 / 5000 | – | ||
SO2 | 0-500 / 5000 | – | ||
CO | 0-75 / 1000 | – | ||
NH3 | 0-15 / 500 | – | ||
H2O (%) | 0-30 / 40 | – | ||
CO2(%) | 0-10 / 100 | – | ||
O2(%) | 0-10 / 25 | – |
Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)
(*) Min/Max based on 100/200 Dilution Rate (other ranges & dilution rates available upon request)
TECHNICAL SPECIFICATIONS | |
---|---|
QAL1 to EN 15267-3 certified | YES |
US EPA compliance | YES |
Sampling technology | Hot/Wet Extraction |
Sample transfert | 180°C heated sampling line |
back flush function | YES |
span injection | YES on analyser or at sample point |
Built-In O2 option | YES |
Serial link communication | RS232 / RS422 |
Other Communication | Ethernet |
Analogue OUTPUTS | YES (x 8) |
Analogue INPUTS | YES (x 4) |
Dimensions (mm) | Tight box: 710 x 560 x 300 (D x W x H) |