Environmental Monitoring Solutions
The sensors manufactured by Palas® operate on the proven principle of single particle measurement using the scattered light method with high resolution to determine the distribution of particle size and concentration. For years they have been used in industry and science for the analysis and evaluation of airborne particles as well as in official and continuous fine dust monitoring according to the EN 16450 standard.
Like all sensors of the Fidas® line, the sensors can be easily calibrated on site using monodisperse particles and thus allow a constant and stable measurement of particle concentration values and mass fractions of PM1 – TSP.
Categories:
Have questions? Call +61 2 9622 6327
| Reported data | CN (Fidas® Sense 2900), PM1, PM2.5, PM4, PM10, TSP, CN, particle size distribution (Fidas® Sense 2300) |
| Measurement range (number CN) | 0 – 200 particles/cm³ (Fidas® Sense 2900), 0 – 20,000 particles/cm³ (Fidas® Sense 2300) |
| Measurement range (size) | 0.3 – 20 µm (Fidas® Sense 2900), 0.18 – 18 µm (Fidas® Sense 2300) |
| Measurement range (mass) | < 10,000 µg/m³ (Fidas® Sense 2300) |
| Volume flow | 2.8 l/min |
| Size channels | max. 235 |
| Time resolution | 10 s |
| Interfaces | USB |
| Protocols | ASCII |
| Light source | Long term stable LED |
| Power supply | 24 V |
| Power consumption | 24 W |
| Installation conditions | +5 – +40 °C (non-condensing) |
| Dimensions | 312 × 176 × 105 mm (H × W × D) |
| Weight | 3.8 kg |
ISO 21501-1