Smart environmental monitoring solutions

Talk to our sales team. Call +61 2 9622 6327

Request a quote
Back to products

JES-301V

Gas Sampling Probe with process shut off valve

  • Representative continuous gas sampling in processes containing dust and humidity
  • Hazardous gases
  • Pressurized processes
  • Extractive gas Analysis
  • Emission (CEMS) and process monitoring
  • Removal of dust from the sample gas

Have questions? Call +61 2 9622 6327

Benefits

  • Safety for operator
  • No clogging of ball valve
  • Efficient use of calibration gas
  • No condensation or chemical reactions of sample gas
  • Convenient filter replacement
  • Low maintenance
  • Safe unattended operation
  • Easy start-up
  • Even for high dust concentrations
  • Reliable protection of the analyzer system

Features

  • Full bore ball valve for process shut-off
  • Manual and actuator operation of ball valve
  • Homogeneous heating without cold spot
  • Large active filter surface
  • Filtration from outside to inside
  • Filter element change without tools
  • Different material of filter elements
  • Electronic temperature controller including over temperature protection
  • Temperature status contact
  • Weather protection housing
  • Various options and upgrades
  • Wide range of accessories
  • Representative continuous gas sampling in processes containing dust and humidity
  • Hazardous gases
  • Pressurized processes
  • Extractive gas Analysis
  • Emission (CEMS) and process monitoring
  • Removal of dust from the sample gas

MODEL

JES-301V

Description

stationary gas sampling probe with process shut-off valve

Operation

Temperature

Low temperature alarm / excess temperature limit

180 °C (ex works), adjustable 5 °C to 200 °C

−30 K /+20 K fix to set point

Operating pressure

max. 2 bara (max. 7 bara optional)

Mounting position

5° to 15° incline (recommended), torsion angle max. 45°

Heating-up time

40 min

for start-up −20 °C to 60 °C
for continuous operation −30 °C to 60 °C

Ambient temperature

Construction

Dimensions over all (W x H x D)

178 x 364 x 396 mm

Dimensions connection box (W x H x D)

120 x 160 x 90 mm

Filter element

2 μm ceramic or 0,2 μm ceramic coated

Active filter surface

170 cm2

Mounting flange

DN 65, PN6; form A according to EN 1092-1; SS316L or 2“ ANSI 150 lbs; according to ASME B16.5

Process shut-off valve

temperature max. 200 °C at 7 bar

Sample gas inlet

G 3/4“ female thread

Sample gas outlet

1/8“ NPT female thread

Calibration gas connection (option)

pipe 6 mm, SS316

Back purge connection (option)

pipe 6 mm, SS316

Gas wetted materials

SS316L, ceramic, Viton®

Protection class

connection box IP65, probe IP43

Weight

12,5 kg

Weather protection housing

SS304, thermal insulated, colour stainless steel natural

Approvals / signs

CE

Electrics

Power supply

230 VAC 50 Hz or 115 VAC 60 Hz

Power consumption

approx. 505 VA

Temperature controller / sensor

electronic / PT100

Electrical connection

spring type terminals, clamping range 0,08 to 2,5 mm2

Switching capacity status contact (volt free)

230 VAC / 2 A, min. 5 VDC / 5 mA