Environmental Monitoring Solutions
Categories:
Have questions? Call +61 2 9622 6327
Benefits
Features
Model |
JES-360 |
| Description | stationary gas sampling probe for pre-filter back flush |
Operation |
|
| Temperature | 180 °C (ex works), adjustable 5 °C to 200 °C |
| Status limiter set values | −30 K /+20 K fixed to set point |
| Operating pressure | max. 2 bara (max. 7 bara optional) |
| Mounting position | 5° to 15° incline (recommended), torsion angle max. 15° |
| Heating-up time | < 1 h |
| Ambient temperature | for start-up −20 °C to 60 °C for continuous operation −30 °C to 60 °C |
Construction |
|
| Dimensions over all (W x H x D) | 375 x 418 x 449 mm |
| Dimensions connection box (W x H x D) | 120 x 160 x 90 mm |
| Filter element | 2 µm ceramic or 0,2 µm ceramic surface coated |
| Active filter surface | 170 cm2 |
| Mounting flange | DN 65, PN6; form A according to EN 1092-1; SS316L or 2“ ANSI 150 lbs; according to ASME B16.5 |
| Sample gas inlet | G 3/4“ female thread |
| Sample gas outlet | 1/8“ NPT female thread |
| Calibration gas connection ( feature C) | pipe 6 mm, SS316 |
| Back purge connection ( feature K) | pipe 6 mm, SS316 |
| Connection pre-filter back flush (feature J) | NPT 3/8“ female thread |
| Gas wetted materials | SS316L, ceramic, Viton® |
| Protection class | connection box IP65, probe IP43 |
| Weight | approx. 15 kg, depending on options |
| Weather protection housing | SS304, thermal insulated, colour stainless steel natural |
| Approvals / Signs | CE |
Electrics |
|
| Power supply | 230 VAC 50 Hz or 115 VAC 60 Hz |
| Power consumption | approx. 805 VA |
| Temperature controller / Sensor | electronic / PT100 (IEC-751) |
| Electrical connection | spring type terminals, clamping range 0,08 to 2,5 mm2 |
| Switching capacity status contact (volt free) | 230 VAC / 2 A, min. 5 VDC / 5 mA |