Smart environmental monitoring solutions

Talk to our sales team. Call +61 2 9622 6327

Request a quote
Back to products

JCT JH3F & JH3FR

Heated Sample Lines with PA-Corrugated Hose

  • For extractive gas analysis
  • For emission and process monitoring
  • For transport of sample gas from the sample point to the analysis system
  • To stay safely above the acid dew point
  • For protection against measured value falsification and frost
  • For indoor and outdoor use

Have questions? Call +61 2 9622 6327

Benefits

  • No condensate formation, no freezing
  • Robust external protection
  • Excellent insulation
  • Optimal heat deployment
  • Customer-specific executions
  • Easy exchange of the inner core (JH3FR)
  • Long lifetime
  • Kink protection

Features

  • Regulated heatable to max. 200 °C
  • External protection corrugated jacket of polyamide
  • Heat insulation with thermo fleece
  • Ready for use
  • Interchangeable inner core for JH3FR
  • Second core for e.g. calibration gas as option
  • Inner core reinforced with stainless steel braid
  • For extractive gas analysis
  • For emission and process monitoring
  • For transport of sample gas from sample point to analysis system
  • To stay safely above the acid dew point
  • For protection against measured value falsification and frost
  • For indoor and outdoor use
MODEL JH3F JH3FR
Description regulated heated sample line
External protection jacket corrugated polyamide jacket, black
Inner core fixed interchangeable
Area of application mobile and fixed indtallation indoor and outdoor
Operation Data
Operating temperature max. 200°C
Operating Pressure max. 10 bara
Ambient temperature* -30°C to +60°C
Construction
Material inner core PTFE, optional PFA
Heating element design according to DIN moisture proof with protection braid
Thermal insulation thermo fleece
End configuration PA hard caps, silicone caps, PG 36 or PG 42 (see table below)
Maximum sample line lenght* 50 m
Diameter core / sample line outside DN 4/6 mm /42mm

DN 6/8 mm / 42mm

Minimum bending radius JH3F / JH3FR DN 4/6 mm; 100 mm / 150 mm

DN 6/8 mm; 150 mm / 200 mm

Dimensions of silicone caps DN 4/6; L = 111,Ø 50 (F),Ø75 (A/B)

DN 6/8; L = 111,Ø 50 (F),Ø75 (A/B)

DN 4/6; L = 111,Ø 50 (F),Ø75 (A/B)

DN 6/8; L = 120,Ø 54 (F),Ø79 (A/B)

Protection class IP 44 (EN60529)
Electrics
Power supply 230 VAC 50/60 Hz or 115 VAC 50/60 Hz
Power consumption 100 W/m
Connection cable 3 m
Connection Plug 7-pole plug for connection of temperature controller HT-43 and HT-55
HANQ8-plug for connection of temperature controller HT-41

* To achieve extended length Norditech offers heated lines with reduced power (W/m) or with a second heating circuit. For lower ambient temperatures versions with higher performance are available.
Please consult Norditech sales team.

 