Environmental Monitoring Solutions
Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2.
Multi-Gas NDIR-GFC analyzer (Non-Dispersive Infrared Gas Filter Correlation) measuring up to ten gases simultaneously, including Nitrogen Oxide (NO), Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2), Carbon Monoxide (CO), even Hydrogen Chloride (HCl) and Hydrogen Fluoride (HF).
Over 4,000 MIR9000 gas CEMS monitors are installed worldwide for process optimization and environmental compliance.
Categories:
Have questions? Call +61 2 9622 6327
Pollutant | Range |
HCI | 0-15 / 5000 |
HF | 0-20 / 300 |
NO | 0-100 / 5000 |
NO2 | 0-100 / 1000 |
N2O | 0-20 / 1000 |
NOx | 0-200 / 5000 |
SO2 | 0-75 / 5000 |
CO | 0-75 / 1000 |
CH4 | 0-10 / 1000 |
THC | 0-50 / 5000 |
CO2(%) | 0-10 / 100 |
O2(%) | 0-10 / 25 |
QAL1 to EN 15267-3 certified | YES |
US EPA compliance | YES |
Sampling technology | Cold/Dry Extraction |
Sample transfert | non heated polytube |
Back flush function | YES |
Span injection | YES on analyser or at sample point |
Built-In O2 option | YES |
Serial link communication | RS232 / RS422 |
Other Communication | Ethernet |
Analogue OUTPUTS | Optional |
Analogue INPUTS | Optional |
Dimensions (mm) | • Tight box version: 200 x 400 x 600 (D x W x H) • 19” rack version: 490 x 483 x 177 (D x W x H) |
Complete CEMS would normally comprise of:
Dual Redundancy System
Under the IED, the maximum period allowed for any one episode of abatement or equipment failure must not exceed four hours. Additionally, the total allowance period for a year must not exceed sixty hours.
The ENVEA duplex philosophy has therefore been specifically developed to assist you in complying with IED by reducing downtime, maximising availability and ensuring you achieve a sound return on your investment.
The MIR 9000 multi-gas CEMS offer compliance with EU Regulation IED (WID / LCPD / MCP directive) BREF Incineration, US EPA (40 CFR 60 & 75)