Environmental Monitoring Solutions
UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Option: H2S / TRS monitoring
Eco-designed, reference air quality monitor, QAL1 certified by the TÜV, US-EPA approved. Utilizes the standard method for the measurement of sulfur dioxides (EN 14212). With its ultra low power consumption & 24 V supply (option), the AF22e is the sole SO2 monitor on the market able to measure without being connected to the power grid.
Categories:
Have questions? Call +61 2 9622 6327
The AF22e is a continuous ambient air-quality monitoring analyzer (CAMs), based on the ultraviolet fluorescence principle, which is the standard method for the measurement of SO2 concentration (EN 14212).
The e-Series of analyzers has been fully eco-designed, with special consideration for the environmental impacts of the product during its whole lifecycle. The exclusive “inside the box” foam modular concept makes the product more robust, power-saving, quieter in operation, simpler to servic
| Measured parameter | SO2 |
| Technology | UV Fluorescence |
| US-EPA Approval / QAL 1 Certification | YES |
| Measurement ranges | 0-1 ppm or 0-10 ppm user-defined |
| Measurement units | ppb, ppm, µg/m3 user-defined |
| Lower Detectable Limit (2σ) | < 0.4 ppb |
| Noise (σ) | < 0.2 ppb |
| Zero drift | < 1 ppb / 24h |
| Span drift | < 0.5% / 7 days |
| Linearity | ± 1% |
| Sample flow rate | 20L/h |
| Sample pump | internal |
| Temperature range | 0°C to +40°C |
| Data storage | 1 year |
| Included I/O | 1LAN/3USB/WIFI/2DRY |
| Weight (Kg) | 9,8 |
| Dimensions mm (LxWxH) | 483 x 545 x 133 |
| Chassis | 19″ Rack, 3U |
| Power supply | 115 V, 60 Hz – 230 V, 50 Hz 24 V optional |
| Pressure and temperature compensation | YES |
COMPLIANCE WITH: