Environmental Monitoring Solutions
With two independent alarm relays, Sintrol’s S201 allows the end user to identify bag leaks and deterioration of filters. Using our electric induction measurement principle, the dust monitor can be easily set up within 30 minutes of installation and gives plant operators quick notification of breaches in the filtration system.
Sintrol dust monitor allows end users to manually adjust alert and alarm level signals to tailor to their end needs. Different probe lengths and coatings give flexibility to meet a variety of applications.
Categories:
Have questions? Call +61 2 9622 6327
Measurement Objects | Total Suspended Particles (TSP) |
Measurement Range | Detection Limit 0.01 mg/m³ Maximum Range up to several g/m³, depending on conditions |
Measurement Principle | Inductive Electrification |
Protection Code | IP65 |
Power supply | 24 VDC and 80-240 VAC |
Power consumption | Up to 10 W |
Output signals | • Two dry contact Relays, max 5A@30VDC / 5A@240VAC • Isolated 4-20 mA output loop |
Communication interface | • Serial communication RS-485 • USB |
Communication protocol | • Modbus RTU (RS-485) • Sintrol network (USB, RF and RS-485) |
Ambient Conditions |
|
Temperature | -40°C to +60 °C (-40 °F to 140 °F) |
Humidity | Max 95% RH (non-condensing) |
Materials and Weight |
|
Enclosure / casing | Aluminum |
Weight | 1.5 kg (3.3 lbs) |
Process conditions |
|
Temperature | Max 200 °C (392 °F) default, optionally up to 700 °C (1292 °F) |
Pressure | Max 300 kPa default, optionally up to 6000 kPa |
Humidity | Max 95% RH (non-condensing) |
AMBIENT CONDITIONS |
|
Temperature | – Starting -20 to +40°C (-4 to 104 °F) – Running -20 to +60°C (-4 to 140 °F) |
Humidity | Max 95 % RH (non-condensing) |
MATERIALS AND WEIGHT |
|
Probe Material | Stainless steel (AISI 316L) |
Body | Aluminum, stainless steel (AISI 316L) |
Weight | 4 kg (8.8 lbs) |