Environmental Monitoring Solutions

Talk to our sales team. Call +61 2 9622 6327

Request a quote
Back to products
JCT-JH3FG-JH3FGR

JCT JH3FG & JH3FGR

Heated Sample Lines with PA-Protection Braid

  • For extractive gas analysis
  • For emission and process monitoring
  • For transport of sample gas from the sample point to the analysis system
  • To stay safely above the acid dew point
  • For protection against measured value falsification and frost
  • For indoor and outdoor use
  • Applicable for portable systems

Have questions? Call +61 2 9622 6327

Benefits

  • No condensate formation, no freezing
  • Close bending radius possible
  • Excellent thermal insulation
  • Optimal heat deployment
  • Customized configurations
  • Easy exchange of the inner core (JH3FGR)
  • Long lifetime also in portable applications
  • Kink protection

Features

  • Regulated heatable to max. 200 °C
  • External jacket flexible protection braid of polyamide
  • Heat insulation with silicone foam
  • Ready for use
  • Very flexible
  • Interchangeable inner core for JH3FGR
  • Second core for e.g. calibration gas as option
  • Integrated temperature controller as option
  • Inner core reinforced with stainless steel braid
  • For extractive gas analysis
  • For emission and process monitoring
  • For transport of sample gas from sample point to analysis system
  • To stay safely above the acid dew point
  • For protection against measured value falsification and frost
  • For indoor and outdoor use
  • Applicable for portable systems

 

MODEL JH3FG JH3FGR
Description regulated heated sample line
External protection jacket Polyamide braid, black
Inner core fixed interchangeable
Area of application mobile and fixed indtallation indoor and outdoor
Operation Data
Operating temperature max. 200°C
Operating Pressure max. 10 bara
Ambient temperature* -30°C to +60°C
Construction
Material inner core PTFE, optional PFA
Heating element design according to DIN moisture proof with protection braid
Thermal insulation close pore, waterproof Silicone hose, thermally stabilised
End configuration hard caps or Silicone caps (see below)
Maximum sample line lenght* 50 m
Diameter core / sample line outside DN 4/6 mm / 42 mm +/- 3 mm
DN 6/8 mm / 42 mm +/- 3 mm
DN 4/6 mm / 42 mm +/- 3 mm
DN 6/8 mm / 48 mm +/- 3 mm
Minimum bending radius JH3FG / JH3FGR DN 4/6 mm; 50 mm / 100 mm

DN 6/8 mm; 75 mm / 120 mm

Dimensions of silicone caps [mm] DN 4/6: L = 88, Ø 50 (H), Ø 70 (C)
DN 6/8: L = 88, Ø 50 (H), Ø 70 (C)
Dimensions of PA hard caps [mm] DN 4/6; L = 111,Ø 50 (F),Ø75 (A)

DN 6/8; L = 111,Ø 50 (F),Ø75 (A)

DN 4/6; L = 111,Ø 50 (F),Ø75 (A)

DN 6/8; L = 120,Ø 54 (F),Ø79 (A)

Protection class IP 44 (EN60529)
Electrics
Power supply 230 VAC 50/60 Hz or 115 VAC 50/60 Hz
Power consumption 100 W/m
Connection cable 3 m
Connection Plug 7-pole plug for connection of temperature controller HT-43 and HT-55
HANQ8-plug for connection of temperature controller HT-41
Option integrated temperature controller HT 54
Installation site directly on hard cap end
Power supply 230 VAC 50 to 60 Hz / 115 V 60 Hz
Switching capacity max. 1000 W / 5 A (max. 10 m 230 V and 5 m at 115 V)
Temperature range 0°C to 254°C, adjustable in 2°C steps via DIP-switch
Temperature sensor PT 100
Housing materia PA-reinforced glass fiber
Protection class IP 42
optional sealed: IP 65 (fixed temperature adjustment)

DOWNLOADS

You have successfully subscribed to our newsletter!