Smart environmental monitoring solutions

Talk to our sales team. Call +61 2 9622 6327

Request a quote
Back to products

Model 2010 Portable Gas Dilution Calibrator

The 2010 Intelligent Portable Multi-gas Calibrator can easily perform gas dilution, multi source gas blending, ozone and gas phase titration (GPT) for environmental, laboratory, or point source monitoring.

Have questions? Call +61 2 9622 6327

The Model 2010 is small in size and weight for users who require true portability. Enhanced with the latest technology, the Model 2010 calibration system is an uncomplicated and effective way to precisely control the dilution of gas standards for calibration of ambient air and source monitoring analyzers.

The Model 2010 calibrator uses embedded microprocessor technology to precisely deliver and control gas concentrations along multiple curve fits to linearize the desired outputs for the intended purpose. The unit can be operated manually, automatically, or semi-automatically by remote access. It also has the capability to produce and store in memory 20 calibration sequences with up to 20 levels of source/dilution in each sequence.

Users can choose either the front panel membrane keypad, external keyboard, serial port, or Ethernet to input calibration sequences.

The instrument’s pneumatic system uses Mass Flow Controllers to precisely meter gas streams and implements multiple types of curve correction algorithms to linearize calibrations. A second source MFC can be added for a wider dynamic range or trace level applications. An optional second source MFC with blending allows userperformed interferent testing and evaluation.

Calibrator design exceeds US EPA calibration method requirements. Dilution components are calibrated with standards and test equipment traceable to the National Institute of Standards and Technology.

 

Standard Features

Pneumatics

  • Diluent Mass Flow Controller, 0-10 SLM
  • Source Mass Flow Controller, 0-100 SCCM
  • 4 Calibration Gas Input Ports and 1 Purge Port
  • 3 Output Ports and 1 Vent Port
  • 1 Diluent Gas Input Port

Electronics/Communication

  • Standard 98-264 VAC, 150-300 VA, 50/60 Hz Operation
  • Bright Color Display
  • 42-Button Membrane Keypad
  • 8 Bits Digitasl Input/Output
  • 1 Serial Port
  • External PC Keyboard Port
  • Parallel Printer Port
  • Air Source Control Port

Optional features

  • Alternate Diluent Mass Flow Controller, Ranges 0-20 SLM
  • Alternate Source Mass Flow Controller, Ranges 0-1 SLM
  • Second Source Mass Flow Controller, Ranges 0-1 SLM
  • Additional Calibration Gas Input Ports
  • Multi-Source Blending
  • Permeation Port
  • Additional Status I/O Bits up to 24 Total
  • Internal Instrument Solenoid Driver
  • Internal Ozone Generator with Gas Phase Titration (GPT) capability
  • Ozone Generator UV Optical Servo Control Loop
  • High-impact transport case
  • Rack Mount Version with Internal UV Photometer (Model 2010D)
                Specifications subject to change without notice
Dilution System
Input Dilution Gases 1 Standard
Input Source Gases 1 Standard, 1 Purge
Additional Inputs 2 Additional
Dilution Mass Flow Controller 0-10 SLPM (standard)
Optional Ranger 0-20 SLPM
Source Mass Flow Controller 0-100 SCCM (standard)
Optional Ranges 0-2 SLPM
2nd Source Mass Flow Controller 0 thru 2 SLPM
Flow Accuracy < ±1% full scale
Flow Repeatability < ±0.15% full scale
Linearity < ±0.5% full scale
Input Pressure 12-35 PSIG
Output Manifold 3 Outputs, 1 Vent (standard)
Optional Outputs 1 Permeation Port
Optional Internal Ozone Generator
Output 2 ppb – 1000 ppb @ 5 SLPM
Accuracy ± 1% of Set Point or ± 2 ppb @ 5 SLPM
Nominal Flow 100 SCCM, ± SCCM
UV Lamp Temperature 50°C, ± 0.1°C
Calibrator Interface
Operation Manually thru 42-button membrane keypad, keyboard, serial ports
Calibration Definitions 20 factory-defined calibration sequences with up to 20 points per sequence
Calibration Types Gas Dilution, Ozone, GPT
Gas Definitions 1 Dilutent Gas 20 Source Gases
Auto Calibrations 20 timer driven cal routines performing user-defined calibration sequences on a programmable schedule
Digital Inputs/Outputs 8 status I/O bits control calibrator functions using contact closures or TTL logic
Digital Input Types contact closure or TTL logic
Optional I/O Additional 16 status I/O bits for a total of 24 I/O bits
Communications RS232, Optional Ethernet TCP/IP
Physical & Operational Specifications
Operating Temperature 5°C to 40°C
Dimensions 6.2 (15.6 cm) H 14.3 (36.4 cm) W 12.4 (31.6 cm) D
Average Weight 19 lbs. (8.6 kg)
Input Voltage 98-264 VAC, 100 VA, 50/60 Hz Operation