Smart environmental monitoring solutions
The Model 2020 is a portable source for clean, dry air designed to meet a wide range of requirements for the environmental industry including trace level applications. From supplying zero air for calibration systems to purge air for permeation ovens, the small package size and weight make the Model 2020-EXP the preferred choice for field and audit personnel as well as operating environments with limited bench space.
The Model 2020-EXP uses an internal permeation drying system for moisture removal and is coupled with filter canisters for scrubbing NO, NO2, O3, SO2, and H2S. Optional features such as the internal carbon monoxide (CO) oxidizer or external hydrocarbon (HC) oxidizer further the Model 2020’s clean air capabilities.
Categories:
Have questions? Call +61 2 9622 6327
Talk to our sales team. Call +61 2 9622 6327
The 2010D Intelligent Gas Dilution Calibrator can easily perform gas dilution, multi-source gas blending, ozone and gas phase titration (GPT - NO + O3 to generate NO2) for environmental, laboratory, or point source monitoring. The Model 2010D represents the latest generation of calibrator technology for environmental, laboratory or point source monitoring. The unit has two internal mass flow controllers (MFC's), with options for an internal Ozone generator and a photometer (5.25 inches high and weighing less than 25 lbs). The Model 2010D calibrator uses embedded microprocessor technology to precisely deliver and control gas concentrations along multiple curve fits to linearize the desired outputs for the intended purpose. The unit can be operated manually, automatically, or semi-automatically by remote access. It also has the capability to produce and store in memory 20 calibration sequences with up to 20 levels of source/dilution in each sequence. Users can choose either the front panel membrane keypad, external keyboard, serial port, or Ethernet to input calibration sequences. The instrument’s pneumatic system uses Mass Flow Controllers to precisely meter gas streams and implements multiple types of curve correction algorithms to linearize calibrations. A second source MFC can be added for a wider dynamic range or trace level applications. An optional second source MFC with blending allows user-performed interferent testing and evaluation. Calibrator design exceeds US EPA calibration method requirements. Dilution components are calibrated with standards and test equipment traceable to the National Institute of Standards and Technology. Sabio's calibrators allow the user to view the value of NO2 generated during GPT and displays the dilution of all gases present when using a multi-blend cylinder.
Users can easily perform precise gas dilution, ozone, and gas phase titration (GPT) calibrations with the Model 4010 Gas Dilution Calibrator. Enhanced with the latest technology, the Model 4010 was designed to set a new standard of quality and performance for a variety of applications in ambient air monitoring including trace levels, continuous emission monitoring (CEM), fugitive emissions, odor and process monitoring. The Model 4010 calibrator uses embedded microprocessor technology to accurately deliver and control gas concentrations, along with multiple curve fits to linearize the desired output for the intended purpose. The unit can be operated manually or automatically to conduct calibrations or audits that exceed U.S. Environmental Protection Agency (EPA) method requirements. Highly accurate mass flow controllers (MFC’s) along with an optional ultraviolet (UV) ozone generator and photometer ensure reliable, repeatable gas concentrations. The Model 4010 can store 20 calibration sequences, with up to 20 concentration levels in each sequence. Local or remote operation is accomplished using the front panel keypad, external keyboard, RS-232 or Ethernet ports. Intuitive, menu driven software allows uncomplicated programmability and access to real-time diagnostics.
Users can easily perform precise gas dilution, ozone, and gas phase titration (GPT) calibrations with the Model 4010T Gas Dilution Calibrator. Enhanced with the latest technology, the Model 4010T was designed to set a new standard of quality and performance for a variety of applications in ambient air monitoring including trace levels, continuous emission monitoring (CEM), fugitive emissions, odor and process monitoring. The Model 4010T calibrator uses embedded microprocessor technology to accurately deliver and control gas concentrations, along with multiple curve fits to linearize the desired output for the intended purpose. The unit can be operated manually or automatically to conduct calibrations or audits that exceed U.S. Environmental Protection Agency (EPA) method requirements. Highly accurate mass flow controllers (MFC’s) along with an optional ultraviolet (UV) ozone generator and photometer ensure reliable, repeatable gas concentrations. The Model 4010T can store 20 calibration sequences, with up to 20 concentration levels in each sequence. Local or remote operation is accomplished using the front panel keypad, external keyboard, RS-232 or Ethernet ports. Intuitive, menu driven software allows uncomplicated programmability and access to real-time diagnostics.
The Model 1000M methane catalytic oxidizer is an easy to use, reliable method for the removal of methane or carbon monoxide. Ideal for use with any of Sabio’s air sources, this oxidizer is extremely effective in furthering the reduction of air pollutants for clean air applications. The Model 1000M methane oxidizer meets industry requirements for thermal oxidation with increased oven reliability and stability, faster rise times, and higher converter efficiencies. Average converter efficiency is 95% or greater. The proprietary two-stage, multiple path tube and oven design enable the Model 1000M the ability to oxidize reactive species at relatively low temperatures. Oven temperature is precisely maintained by a microprocessorbased temperature controller driving a high-capacity optically isolated triac control module. The dual display temperature controller uses pulse width modulation to regulate the heating cycle and minimize thermal noise from on/off cycling. A thermal cutoff switch works with the heating element to protect the electronic circuitry and oven from thermal overload conditions.
The Model 2020 is a portable source for clean, dry air designed to meet a wide range of requirements for the environmental industry. From supplying air for calibration systems to purge air for permeation ovens, the small package size and weight make the Model 2020 the preferred choice for field and audit personnel as well as operating environments with limited bench space. The Model 2020 uses an internal permeation drying system for moisture removal and is coupled with filter canisters for scrubbing NO, NO2, O3, SO2, and H2S. Optional features such as the internal carbon monoxide (CO) oxidizer or external hydrocarbon (HC) oxidizer further the Model 2020’s clean air capabilities.
The 2010 Intelligent Portable Gas Dilution Calibrator can easily perform gas dilution, multi source gas blending, ozone and gas phase titration (GPT) for environmental, laboratory, or point source monitoring The Model 2010 is small in size and weight for users who require true portability. Enhanced with the latest technology, the Model 2010 calibration system is an uncomplicated and effective way to precisely control the dilution of gas standards for calibration of ambient air and source monitoring analyzers. The Model 2010 calibrator uses embedded microprocessor technology to precisely deliver and control gas concentrations along multiple curve fits to linearize the desired outputs for the intended purpose. The unit can be operated manually, automatically, or semi-automatically by remote access. It also has the capability to produce and store in memory 20 calibration sequences with up to 20 levels of source/dilution in each sequence. Users can choose either the front panel membrane keypad, external keyboard, serial port, or Ethernet to input calibration sequences. The instrument’s pneumatic system uses Mass Flow Controllers to precisely meter gas streams and implements multiple types of curve correction algorithms to linearize calibrations. A second source MFC can be added for a wider dynamic range or trace level applications. An optional second source MFC with blending allows user-performed interferent testing and evaluation. Calibrator design exceeds US EPA calibration method requirements. Dilution components are calibrated with standards and test equipment traceable to the National Institute of Standards and Technology.
We’ll get back to you within two business days with pricing info on your chosen products, along with details on related services.
By submitting, you consent to Norditech processing your information in accordance with our Privacy Policy.
We use your Email only to inform about new products of Norditech, special offers, and provide value through articles and publications.