PEM Rack 19 inch Hydrogen generator

H2 POWER 10L is a system able to provide up to 1Nm3/h of hydrogen. The hydrogen is produced from three Hydrogen Generators “6920.16.330” connected in parallel mode. 6920.16.330 uses an electrolytic cell with polymeric membrane (PEM) to produce pure hydrogen from distilled water. No acid or alkaline solutions are used. It is provided with an internal 1.1 litres tank with electronic level control and an automatic fill function “Autorefill” from an external source.

Its innovative gas drying system is completely maintenance-free and allows continuous operation, 24 hours a day. The exclusive, electronically-controlled, gas/liquid separator automatic checks for internal leaks whenever starting the unit, and a constant control of operating parameters guarantees maximum safety. The touch-screen LCD interface provides a direct simple control and management of all functions on the unit. The RS232 and LAN ports allow a remote control of the system from anywhere in the world.

Categories:

Have questions? Call +61 2 9622 6327

PRODUCT FEATURES

  • Up to 1Nm3/h of hydrogen
  • New long life multilayer PEM cell
  • High pressure GLS electronically controlled (patented)
  • Automatic fill function “Autorefill”
  • Innovative gas drying system is completely maintenance-free
  • Remote control
H2 Power 10L
Hydrogen principal data
Electrolytic cell PEM technology (No acid or alkaline solutions are used)
H2 purity >99.99999%. Referred to O2, DewPoint < -75°C
Outlet pressure (max) 12Bar (optional 16 Bar)
H2 flow rate (max) 1 Nm3/h (3 x 3300cc/min)
Drying system Maintenance-free
I/O communication
Touch-screen LCD 128×64 pixel Standard
Output pressure gauge
RS232
LAN
Software/safety functions
Internal H2 sensor Optional
Cell voltage control Standard
Automatic fault detection
Power supply temperature detection
Automatic safety de-pressurization
Water level control
Automatic tank refill
Fill canister function
Connections
H2 outlet port 1/8” compression tube fitting
Water inlet port 1/4” tube, quick release push to lock fitting
Water
Quality Deionized, ASTM II, <0.1uS
Generator internal tank capacity 3.3 l (3 x 1.1 l)
External tank capacity (for refilling) 10 l
Consumption rate 1l/hour
Electrical data
Power supply connection type 3 x wires 4mm3 (2 wire+ground)
Power supply voltage Single phase 230VAC, 50/60 Hz
Power supply current (max) 30A
Energy required 5.8kWh/Nm3 (end life 6.7kWh/Nm3)
General data
Operating temperature 5-35°C (41-95°F)
Storage temperature 1-40°C (33.8-104°F)
Operating humidity (non-condensing) 80% at 25°C (77°F)
Ingress protection rating IP20
Pollution degree rating 2 (with no aromatic compounds)
Cabinet ventilation 2 x 135 Nm3/h controlled with thermostat
Dimensions (w * h * d) 59 * 164 * 81 cm
Net weight (water tanks empty) <180kg
Altitude <2000m
Certifications CE, ISO9001

*1 Referred to O– DewPoint < -25°C (<-13°F), Atmospheric Dew Point (ADP)

H2 Power 10L consist of:

N. Qty. Description
1 1 Closet Rack 28 unit
2 1 Power supply 3 units, 6920.30.002
3 3 Hydrogen Generator 5 units, 6920.16.330
4 1 Rack tank 24L 3 units (for Generators refilling) 6920.11.002
5 1 Pipeline kit for cascading, 6930.00.030
6 1 Master Box controller with LAN, 6930.00.025
7 2 Cooling fans

DOWNLOADS