Model | HT41 | HT42 | ||||||
Description | temperature controller with limiter function | |||||||
Order code | ||||||||
Connections | HANQ8-socket (8-pole+PE) and mains cable | with cable glands | ||||||
CONSTRUCTION | ||||||||
Installation | wall mounting, 4 x M4 | |||||||
Dimensions | 80 x 182 (211) × 60 mm | |||||||
Mounting surface | 100 x 162 mm | |||||||
Degree of protection | P 65 (EN 60529) | |||||||
Protection class | I | |||||||
Operation | Film keypad, 4 push buttons | |||||||
Housing material | Makrolon | |||||||
Approvals | CE | |||||||
Dimensions over all (W x H x D) | rear panel mounting: 277 x 307 x 360 mm side panel mounting: 403 x 307 x 234 mm | |||||||
Installation | stand alone or wall mounting | |||||||
Mounting position | horizontal | |||||||
Weight | 17,5 kg | 18 kg | ||||||
Housing / Colour | stainless steel / natural | |||||||
Dead volume per gas path | 67 ml | 2 x 50 ml | ||||||
Connection sample gas inlet | PVDF and 1.4401: 6 mm tube; glass: GL14 with hose connection | |||||||
Connection sample gas outlet and condensate outlet on top (standard) | PVDF: PVDF hose fitting DN 4/6; 1.4401: 6 mm tube; glass: GL14 with hose connection | |||||||
Connection condensate outlet at the bottom (on request) | PVDF and 1.4401: 12 mm tube; glass (only Mono available): GL18 with hose connection | |||||||
Protection class | IP 20 (EN 60529 / EN 61010) | |||||||
Approvals / Signs | CE | |||||||
ELECTRICS | ||||||||
Power supply | 230 VAC 50 Hz, optional 115 VAC 60 Hz | |||||||
Noise immunity | EN 50 082-2 | |||||||
Emitted interference | EN 50 081-1 | |||||||
Sensor types | Fe-CuNi (J), NiCr-Ni (K), with reference point compensation and sensor breakage safeguard, sensor polarity reversal control PT 100, 2 conductors DIN/IEC |
|||||||
Fault limit | 0.1 % to 0.2 % of the range | |||||||
Controller outlet | electrical switch (control) 16 A. Triac | |||||||
Alarm outlet | relais 6 A, limit compensation Y3, ‡10K of rated value | |||||||
Controller response | PID | |||||||
Limiter function | signal via 2. PT 100 | |||||||
Cutout temperature limiter | 50°C to 500°C adjustable, actuates via mechanical relay 16 A | |||||||
Display current / rated value | 4-digit LED display (13 mm high) | |||||||
Measuring range | -199 to +999 digit | |||||||
Deviation display | 7 LED +12°C flashing | |||||||
Setting ex works* | PT 100. 0°C to 200°C | |||||||
Option | external set point input |
“The customer can reprogram these parameters or settings are supplied as required (extra charge).”