Model | JES-360H |
Description | stationary gas sampling probe for pre-filter back flush |
Operation | |
Temperature | 180 °C (ex works), adjustable 5 °C to 315 °C |
Status limiter set values | −30 K / +20 K fixed to set point |
Operating pressure | max. 2 bara (max. 7 bara optional) |
Mounting position | 5° to 15° incline (recommended), torsion angle max. 45° |
Heating-up time | < 1 h |
Ambient temperature | for start-up −20 °C to 60 °C for continuous operation −30 °C to 60 °C |
Construction | |
Dimensions over all (W x H x D) | 375 x 418 x 449 mm |
Dimensions connection box (W x H x D) | 120 x 160 x 90 mm |
Filter element | |
Active filter surface | 170 cm2 |
Mounting flange | DN 65, PN6; form A according to EN 1092-1; SS316L or 2“ ANSI 150 lbs; according to ASME B16.5 |
Sample gas inlet | G 3/4“ female thread |
Sample gas outlet | 1/8“ NPT female thread |
Calibration gas connection ( feature C) | pipe 6 mm, SS316 |
Back purge connection ( feature K) | pipe 6 mm, SS316 |
Connection pre-filter back flush (feature J) | NPT 3/8“ female thread |
Gas wetted materials | SS316L, ceramic, Perlast® |
Protection class | connection box IP65, probe IP43 |
Weight | approx. 15 kg, depending on options |
Weather protection housing | SS304, thermal insulated, colour stainless steel natural |
Approvals / Signs | CE |
Electrics | |
Power supply | 230 VAC 50 Hz or 115 VAC 60 Hz |
Power consumption | approx. 805 VA |
Temperature controller / Sensor | electronic / PT100 (IEC-751) |
Electrical connection | spring type terminals, clamping range 0,08 to 2,5 mm2 |
Switching capacity status contact (volt free) | 230 VAC / 2 A, min. 5 VDC / 5 mA |